Why So Many Houses From This Era Have Problems

When we open up a wall or a ceiling in a house built between the 1970s and the early 2000s, we often find the same few problems again and again. They were not the result of sloppy builders. Most of them were the result of builders following the best advice of the day. The energy crisis of the 1970s pushed houses to be tighter and better insulated, and at the same time the materials changed: solid board sheathing gave way to plywood and then OSB, plaster gave way to drywall, and new siding and trim products arrived. The building codes and the building science that explained how moisture moves through walls caught up only later.

What follows are the failures we see most, and what is behind them. Not every house has every problem, but if your house is from this era, it is worth knowing what to look for.

Rot at the Bottom of the Wall

One of the most common failures is a wall that rots from the bottom up. It begins at the bottom plate, the horizontal board the wall is built on, and works its way up through the lower sheathing, sometimes a few feet. The siding on the outside may look fine until it is pulled away.

Rotted wood along the bottom of a wall, exposed where the siding was removed, with broken pieces of wood on the gravel below
Rot found along the bottom of a wall once the siding was removed.

The cause is water collecting where the wall meets the foundation, and several details have to fail together:

  • No capillary break. Wood sitting directly on concrete wicks moisture upward. Modern practice puts a barrier between the foundation and the wood. In older houses there often is none.
  • Siding too close to the ground. When soil, mulch, a patio, or a walkway rises to meet the siding, rain splashes up onto the wall and there is no room for the wall to dry. Siding and trim are generally meant to stay several inches above grade.
  • Splashback from hard surfaces. Rain bouncing off a concrete slab, a stoop, or a deck can soak the bottom few inches of a wall again and again.
  • Missing kickout flashing. Where a roof ends against a wall, a small piece of metal called a kickout flashing sends the water into the gutter. Without it, the water runs down behind the siding and ends up at the base of the wall. Rot at the bottom corner under a roof edge is a classic sign.
  • No drainage gap behind the siding. When siding is fastened tight against the sheathing, water that gets behind it has nowhere to drain and no way to dry.
  • Panel sheathing. Plywood and especially OSB absorb water through their edges and swell. Once wet, a panel can hold moisture and carry it upward.

Some of the siding products of the 1980s and 1990s, including certain hardboard and composite sidings and some plywood panel sidings, were also prone to swelling and rotting at their lower edges, and a number of them ended up in class action settlements.

Decayed framing and sheathing at the bottom of an exterior wall, with pink insulation above and foundation block below
Decayed framing and sheathing at the bottom of an exterior wall, just above the foundation block.
A rotted wall stud and the bottom plate it stands on
A rotted stud and the bottom plate it stands on.

Plastic Behind the Drywall

For decades the standard advice in cold climates was to staple a sheet of polyethylene plastic over the insulation, under the drywall, as a vapor barrier. The idea was sound enough, warm humid indoor air carries water vapor, and in winter that vapor can condense inside a cold wall. Stop the vapor and you stop the condensation.

The problem is that the same plastic stops the wall from drying. Walls get wet from the outside too, through leaks around windows, through siding, and through the failures described above. In the summer, with the air conditioning on, the direction of the vapor drive flips. Hot, humid outdoor air pushes inward, meets the cool plastic and drywall, and condenses on the plastic sheet creating a damp space filled with water vapor. A wall with a vapor barrier on the inside and a tight, water-resistant sheathing on the outside can trap moisture from either side with no way to release it.

The details matter here. In a climate like northern Ohio, controlling vapor on the inside of a wall has been standard for a long time and it is not automatically wrong. Building scientists now stress that air leaks move far more moisture than vapor diffusion does, so sealing the air leaks matters more than the plastic. Current building science favors a vapor control layer matched to the wall, sometimes a smart membrane that changes its permeability with the seasons, and often some insulation on the exterior side of the sheathing to keep the wall warm. The failures happen when a wall is closed up with poly creating a surface for water vapor to condense on and preventing that space from drying out once it gets wet. The result is mold, rotted framing, and damp insulation hidden behind walls that look perfect.

Attic Ventilation and Rot at the Ridge

An unconditioned attic is supposed to stay close to the outdoor temperature, so that the roof deck stays cold and dry in winter. That depends on fresh air entering the attic at the soffits and exiting at the ridge through a ridge vent. In many houses from this period that system was incomplete, backwards, or simply done incorrectly.

  • A ridge vent with no soffit intake. A vent at the top cannot pull air through an attic that has no way in at the bottom. Building scientists and trade publications agree that a ridge vent without soffit vents does not work, and in windy conditions it can even pull moist air up from the house.
  • Blocked soffits. Insulation pushed up into the eaves seals the intake. Baffles that hold the insulation back are the fix. Bonus points if when building the house you install raised heel trusses which solves this problem without any compromises.
  • Moisture sources that end up in the attic. Bathroom fans and sometimes dryer or kitchen vents that exhaust into the attic instead of outdoors, and countless small air leaks around lights, wiring, plumbing, and the attic hatch let warm, damp air rise into the cold space.
  • More insulation with no more ventilation. Over the decades, insulation was added to the attic floor, which made the roof colder and the moisture problem worse.

In winter that moisture condenses and freezes on the underside of the roof deck. In spring it melts and soaks the wood. The highest point of the roof, where the warm, wet air collects, tends to rot first, which is why we call it ridge rot. By the time stains show up on the ceiling below, the damage is often well advanced and the fix is a complete demo and rebuild.

A Few Others Worth Knowing

  • Polybutylene plumbing. A grey plastic water supply pipe used in many houses from the late 1970s into the mid 1990s. It was prone to failure at the fittings and was the subject of major class action litigation.
  • Fire retardant treated roof plywood. Used on some roofs in the 1980s, it was later found to degrade under heat in the attic.

What to Do About It

Most of these problems are found early with a careful look. Check that the siding clears the ground, that the roof edges have kickout flashing, that the soffits are open, and that the bathroom fans actually vent outside. In the attic in winter, frost on the underside of the roof deck is a clear warning sign. Soft or discolored wood at the bottom of an exterior wall deserves a probe with a screwdriver.

If you are already planning a remodel, an opened wall is the best time to see what is behind it and to fix the underlying problem, not cover it up. That is one of the reasons we pay close attention to what we find before we close things in.

Thinking about a project like this?

We'd be glad to talk it through. No pressure, no sales pitch.

Start a Conversation